Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

310705

Siemens 310705 - Axis drive monitoring cycle times of axes differ

Axis drive monitoring cycle times of axes differ

The monitoring cycle MD 5002: MONITOR_CYCLE_TIME must be identical for both axes on 2-axis modules Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The monitoring cycle MD 5002: MONITOR_CYCLE_TIME must be identical for both axes on 2-axis modules

Troubleshooting Steps

  1. 1Modify MD 5002: MONITOR_CYCLE_TIME for both axes.
  2. 2Switch control OFF - ON. 2-785

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.