Siemens 300858 - Axis drive generator mode: response voltage > switch-off
This alarm occurs when the sum of response voltage and hysteresis exceeds the deactivation threshold for generator mode in the drive parameters. Adjust the values in MD1631, MD1632, or MD1633 to resolve.
Siemens 300858 - Axis drive generator mode: response voltage > switch-off
Axis drive generator mode: response voltage > switch-off
The sum of the values in MD1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) + MD1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for generator control) is greater than MD1633: $MD_LINK_VOLTAGE_GEN_OFF (deactivation threshold for generator axis) Control reaction: Interface signals are set. Alarm display.
Root Cause Summary
This alarm occurs when the sum of response voltage and hysteresis exceeds the deactivation threshold for generator mode in the drive parameters. Adjust the values in MD1631, MD1632, or MD1633 to resolve.
Safety
Causes and Fixes
Access machine data
Navigate to the machine data settings in the Siemens control panel.
Check values
Verify the values in MD1631, MD1632, and MD1633 for the affected axis and drive.
Adjust parameters
Reduce MD1631 or MD1632, or increase MD1633 to ensure the sum is below the threshold.
Restart system
Clear the alarm and restart the system to apply changes.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.