axismd.ai
Siemens SINUMERIK Controller
Program/G-code · Intermediate · 30-120 minutes
Siemens 840D 300752 - Axis drive blocking frequency of setpoint current filter too high
This alarm occurs when the blocking frequency of a current setpoint filter exceeds the allowable limit due to incorrect machine data or parameter settings. Correct the related machine data to resolve it.
Siemens 840D 300752 - Axis drive blocking frequency of setpoint current filter too high
Axis drive blocking frequency of setpoint current filter too high
Siemens SINAMICS drive alarm 300752: Axis drive blocking frequency of setpoint current filter too high. This alarm indicates a fault condition in the SINAMICS servo drive system. Refer to the Siemens SINAMICS fault list documentation for the complete remedy.
Root Cause Summary
This alarm occurs when the blocking frequency of a current setpoint filter exceeds the allowable limit due to incorrect machine data or parameter settings. Correct the related machine data to resolve it.
Safety
Causes and Fixes
Check Machine Data
Access the machine data (MD 1000) for the specified axis and drive via the control panel.
Adjust Frequency Value
Ensure the blocking frequency is less than the reciprocal of 2 current controller cycles (1/(2*MD1000*31.25µs)).
Reset and Test
Save changes, reset the alarm, and test the program to confirm resolution.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.