Siemens 300751 - Axis drive speed control gain too high
This alarm occurs when the speed control gain (MD 1407 or MD 1408) is set too high, causing instability in the axis drive. Reduce the gain values to resolve the issue.
Siemens 300751 - Axis drive speed control gain too high
Axis drive speed control gain too high
The proportional gain of the speed controller MD 1407: $MD_SPEEDCTRL_GAIN_1 (P gain of speed controller) or MD 1408: $MD_SPEEDCTRL_GAIN_2 (P gain of upper adaption speed) has been set too high Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Root Cause Summary
This alarm occurs when the speed control gain (MD 1407 or MD 1408) is set too high, causing instability in the axis drive. Reduce the gain values to resolve the issue.
Safety
Causes and Fixes
Access machine data
Navigate to MD 1407 ($MD_SPEEDCTRL_GAIN_1) and MD 1408 ($MD_SPEEDCTRL_GAIN_2) in the control parameters.
Reduce gain values
Lower the gain settings incrementally (e.g., reduce by 10-20%) to stabilize the system.
Test and restart
Clear the alarm, test the axis movement, and restart the program.