Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-120 minutes
Siemens 300756 - Axis drive speed hysteresis of setpoint current smoothing invalid
The value in MD 1246: $MD_CURRENT_SMOOTH_HYSTERESIS (hysteresis of the speeddependent M setpoint smoothing) is greater than or equal to the value in MD 1245: $MD_CURRENT_SMOOTH_SPEED (threshold of the speed-dependent M setpoint smoothing) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.
Siemens 300756 - Axis drive speed hysteresis of setpoint current smoothing invalid
Axis drive speed hysteresis of setpoint current smoothing invalid
The value in MD 1246: $MD_CURRENT_SMOOTH_HYSTERESIS (hysteresis of the speeddependent M setpoint smoothing) is greater than or equal to the value in MD 1245: $MD_CURRENT_SMOOTH_SPEED (threshold of the speed-dependent M setpoint smoothing) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.