300736

Siemens 300736 - Axis drive Lh characteristic invalid

Axis drive Lh characteristic invalid

The value in MD 1143: $MD_LH_CURVE_UPPER_SPEED (LH curve upper speed) is less than or equal to the value in MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field weakening) or the value in MD 1144: $MD_LH_CURVE_GAIN (LH curve gain) is less than 100 Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • The value in MD 1143: $MD_LH_CURVE_UPPER_SPEED (LH curve upper speed) is less than or equal to the value in MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field weakening) or the value in MD 1144: $MD_LH_CURVE_GAIN (LH curve gain) is less than 100

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
  3. 3For third-party motors: - Modify MD 1143: $MD_LH_CURVE_UPPER_SPEED (Lh curve upper speed) - Modify MD 1144: $MD_LH_CURVE_GAIN (Lh curve gain) - Modify MD 1142: $MD_FIELD_WEAKENING_SPEED (threshold speed for field weakening) should be checked and, if necessary corrected.
  4. 4Switch control OFF - ON. 2-733

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.