Siemens 300742 - Axis drive voltage/frequency mode: converter frequency invalid
Only converter frequencies (MD 1100: $MD_PWM_FREQUENCY (pulse width modulation frequency)) of 4 kHz or 8 kHz are permissible in V/f mode (selected via MD 1014: $MD_UF_MODE_ENABLE) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Siemens 300742 - Axis drive voltage/frequency mode: converter frequency invalid
Axis drive voltage/frequency mode: converter frequency invalid
Only converter frequencies (MD 1100: $MD_PWM_FREQUENCY (pulse width modulation frequency)) of 4 kHz or 8 kHz are permissible in V/f mode (selected via MD 1014: $MD_UF_MODE_ENABLE) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.