Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

300746

Siemens 300746 - Axis drive SBH/SG not enabled

Axis drive SBH/SG not enabled

In the machine data 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable) the function SBH/SG has not been enabled although the function SE/SN has been selected in this MD. Request: During boot-up of the control Control reaction: Mode group not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • In the machine data 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable) the function SBH/SG has not been enabled although the function SE/SN has been selected in this MD.
  • Request: During boot-up of the control

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2Enable the function SBH/SG via MD 1301: $MD_SAFE_FUNCTION_ENABLE (safe functions enable).
  3. 3Switch control OFF - ON

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free