Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

300720

Siemens 300720 - Axis drive maximum motor speed invalid

Axis drive maximum motor speed invalid

Because of the high maximum motor speed in the drive MD 1401: $MD_MOTOR_MAX_SPEED and the speed controller cycle in MD 1001: $MD_SPEEDCTRL_CYCLE_TIME sufficiently high speeds can occur to cause a format overflow. Example: A motor speed of 480,000 rpm can still be processed without error at a speed controller cycle time of 125 µs Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • Because of the high maximum motor speed in the drive MD 1401: $MD_MOTOR_MAX_SPEED and the speed controller cycle in MD 1001: $MD_SPEEDCTRL_CYCLE_TIME sufficiently high speeds can occur to cause a format overflow.
  • Example: A motor speed of 480,000 rpm can still be processed without error at a speed controller cycle time of 125 µs

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2Reduce the maximum motor speed MD 1401: $MD_MOTOR_MAX_SPEED (speed for the maximum useful motor speed) or set a smaller speed controller cycle in MD 1001: $MD_SPEEDCTRL_CYCLE_TIME (speed controller cycle).
  3. 3Switch control OFF - ON

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.