Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

300719

Siemens 300719 - Axis drive motor not parameterized for delta operation

Axis drive motor not parameterized for delta operation

On activating the star/delta switchover by drive MD 1013: $MD_ENABLE_STAR_DELTA, the motor delta (motor 2) is not parameterized Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • On activating the star/delta switchover by drive MD 1013: $MD_ENABLE_STAR_DELTA, the motor delta (motor 2) is not parameterized

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2Check and enter the machine data for motor delta (motor 2).
  3. 3Switch control OFF - ON. 2-725

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.