Siemens 300722 - Axis drive zero-load motor current greater than rated current of
On the basis of its no-load current (MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current), the connected motor is too large for the power section in use (continuous thermal current MD 1108: $MD_INVERTER_MAX_THERMAL_CURR (current limit for power section) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Siemens 300722 - Axis drive zero-load motor current greater than rated current of
Axis drive zero-load motor current greater than rated current of
On the basis of its no-load current (MD 1136: $MD_MOTOR_NOLOAD_CURRENT (motor no-load current), the connected motor is too large for the power section in use (continuous thermal current MD 1108: $MD_INVERTER_MAX_THERMAL_CURR (current limit for power section) Control reaction: NC not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.