Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisIntermediate30-120 minutes

300605

Siemens 300605 - Axis drive motor change not valid

Axis drive motor change not valid

An attempt was made to switch over to a motor data record that is not parameterized Control reaction: Mode group not ready. The NC switches to follow-up mode. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm. Channel not ready.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Common Causes

  • An attempt was made to switch over to a motor data record that is not parameterized

Troubleshooting Steps

  1. 1Parameterize the motor data record selected or switch over to another motor.
  2. 2Clear alarm with the RESET key in all channels of this mode group. Restart part program. 2-711

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.