Siemens SINUMERIK Controller
Communication · Basic · 5 - 15 minutes
Siemens 28005 - NCU link: NCU of the link network not running synchronously
Siemens Alarm 28005 (SLS Active) is typically caused by safety interlocks being open, misconfigured safety parameters, or faulty wiring to safety inputs. The most likely fix involves checking the physical state of guards and doors, followed by verifying safety input signals and drive parameters. In many cases, a simple reset or adjustment resolves the issue if no hardware fault is present.
Siemens 28005 - NCU link: NCU of the link network not running synchronously
NCU link: NCU of the link network not running synchronously
Error message of the NCU link module. When the NCU link was powered up, the local NCU (indicated by the alarm) detected that the NCU with the number in the alarm parameter was not running synchronously. This fault in the link can have various causes: - The machine data which configure the NCU link are not identical on all NCUs. - An identical interpolator cycle time has not been selected on all NCUs Control reaction: NC not ready. Channel not ready. NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.
Root Cause Summary
Siemens Alarm 28005 (SLS Active) is typically caused by safety interlocks being open, misconfigured safety parameters, or faulty wiring to safety inputs. The most likely fix involves checking the physical state of guards and doors, followed by verifying safety input signals and drive parameters. In many cases, a simple reset or adjustment resolves the issue if no hardware fault is present.
Safety
Causes and Fixes
Inspect Safety Guards
Visually check all safety doors, guards, and interlocks to ensure they are fully closed and latched. Look for any debris or damage that might prevent proper closure.
Use a flashlight to check for small misalignments or wear on the latch mechanisms that might not be visible at a glance.
Ensure no personnel are inside the guarded area before closing doors to avoid entrapment.
Check HMI Safety Input Status
Access the safety diagnostics screen on the HMI or controller to identify which safety input channel is indicating an open guard. Note the specific input number or name for reference.
Take a screenshot or photo of the diagnostics screen to document the fault for future reference or escalation.
Do not attempt to bypass the safety input signal; this can lead to hazardous conditions.
Perform Safety Reset
After ensuring all guards are closed, perform a safety acknowledgment reset using the designated reset button or key switch as per the machine manual. Monitor if the SLS alarm clears.
If the reset doesn’t clear the alarm, note any additional error messages or status bits that appear during the reset attempt.
Clear the work area before resetting to prevent injury from unexpected motion.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?