28002

Siemens 28002 - Error on activation of machine data, NCU network-wide machine data were modified by

Error on activation of machine data, NCU network-wide machine data were modified by

Siemens SINUMERIK alarm 28002: Error on activation of machine data, NCU network-wide machine data were modified by. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SINUMERIK alarm 28002 fires when the Safe Stop 1 (SS1) safety function is activated on a Sinamics drive, causing a controlled deceleration to standstill followed by Safe Torque Off (STO). This occurs when safety input signals are de-energized, emergency stop circuits are triggered, or PROFIsafe communication commands an SS1 event.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Emergency Stop Status

    Navigate to HMI > Diagnostics > Safety > Emergency Stop Status to verify all E-stop buttons are released and safety gates are closed.

    Never bypass emergency stop circuits for testing purposes

  2. 2

    Verify Safety Input Wiring

    Check terminal X122 on Sinamics drive for SS1 input signals (typically DI Safe 0/1). Measure 24VDC presence on safety input terminals using safety-rated multimeter.

    SS1 inputs require dual-channel safety signals - both channels must be active

  3. 3

    Reset Safety Chain

    After clearing physical safety conditions, acknowledge alarm via HMI > Alarms > Acknowledge, then perform safety reset through HMI > Machine > Safety Reset or via safety PLC.

    Ensure all personnel are clear of machine before safety reset

DIY Feasiblehigh confidence

Call a technician if:

  • ·Safety signature mismatch requiring validation
  • ·PROFIsafe communication hardware failure
  • ·Safety program corruption

Prevention

  • Regular safety circuit testing
  • Maintain clean terminal connections
  • Monitor PROFIsafe communication status
  • Keep safety program backups current

Common Mistakes

  • Bypassing safety inputs for troubleshooting
  • Ignoring dual-channel safety requirements
  • Incorrect safety signature acceptance
  • Using non-safety rated components in SS1 circuits

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.