Communication · Intermediate · 30-120 minutes
Siemens 840D 27900 - PROFIBUS DP: SI fault on axis, code, value, time.
Alarm 27900 indicates a PROFIBUS DP communication fault between the SINUMERIK NCK and a SINAMICS servo drive, with the fault code and timestamp logged by the drive's safety integrity (SI) monitoring. This typically reflects electrical noise, cable degradation, parameter mismatch, or drive-side encoder/commutation errors that interrupt the real-time servo loop.
Siemens 840D 27900 - PROFIBUS DP: SI fault on axis, code, value, time.
PROFIBUS DP: SI fault on axis, code, value, time.
Siemens SINUMERIK alarm 27900: PROFIBUS DP: SI fault on axis, code, value, time. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 27900 indicates a PROFIBUS DP communication fault between the SINUMERIK NCK and a SINAMICS servo drive, with the fault code and timestamp logged by the drive's safety integrity (SI) monitoring. This typically reflects electrical noise, cable degradation, parameter mismatch, or drive-side encoder/commutation errors that interrupt the real-time servo loop.
Safety
Causes and Fixes
Inspect all PROFIBUS DP connectors on the affected axis drive and NCK module for corrosion, bent pins, or loose M12 connectors. Check cable routing to ensure separation from motor power lines and inverter output cables by at least 150mm.
Do not test PROFIBUS continuity with high-ohm meggers; use only low-voltage multimeters or qualified PROFIBUS test equipment.
Verify 120Ω termination resistors are installed on the PROFIBUS DP network—typically at the NCK interface module and the last drive on the line. Access the physical termination switches on each device's DP connector.
In SINUMERIK HMI or Siemens SCOUT TIA, navigate to Diagnostics → Communication → PROFIBUS and check the error counter for this axis. Log the code %2 value (typically 0x80xx range for SI faults) and correlate with SINAMICS drive error logs via STARTER tool.
Replace the PROFIBUS cable segment with certified CAB PB (shielded twisted-pair, 0.34 mm²) and re-terminate. If alarm persists, swap the DP interface module (typically located in the NCK control cabinet) and test.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.