Siemens 840D 27124 - Stop A triggered at least in 1 axis
Alarm 27124 is an informational alarm indicating that Stop A (emergency stop function) has been triggered in at least one axis. The alarm requires Power On acknowledgment and is controlled by the MD parameter $MN_SAFE_ALARM_SUPPRESS_LEVEL which manages alarm priority suppression in the SINUMERIK 840D system.
Siemens 840D 27124 - Stop A triggered at least in 1 axis
Stop A triggered at least in 1 axis
Siemens SINUMERIK alarm 27124: Stop A triggered at least in 1 axis. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 27124 is an informational alarm indicating that Stop A (emergency stop function) has been triggered in at least one axis. The alarm requires Power On acknowledgment and is controlled by the MD parameter $MN_SAFE_ALARM_SUPPRESS_LEVEL which manages alarm priority suppression in the SINUMERIK 840D system.
Safety
Causes and Fixes
Check machine safety circuit and hardwired emergency stop button physical state. Verify no mechanical activation of stop circuits on the machine control cabinet.
Navigate to Diagnostics > Servo > Axis Status in SINUMERIK HMI and verify STOP_A flag status per affected axis. Confirm which axis group triggered the alarm.
Verify safety PLC inputs feeding Stop A signal. Check Input Image (PI) bits mapped to STOP_A function in PLC program via OB35 (Safety) scan. Review parameter MD $MN_SAFE_STOP_A_DELAY_TIME for debounce timing.
Issue Power On command via HMI or NC START key to acknowledge alarm 27124 and re-enable axis servo control after confirming safety conditions are cleared.
Ensure all safety prerequisites are met before Power On; do not bypass safety interlock checks.