Siemens 840D 27201 - PROFIsafe: MD: bus segment error
Alarm 27201 fires when an invalid bus segment value is configured in PROFIsafe-related machine data (MD) parameters. The SINUMERIK 840D expects bus segment MD value to be set to 5 for proper PROFIsafe communication; any other value triggers this alarm during NCK initialization or PROFIsafe handshake.
Siemens 840D 27201 - PROFIsafe: MD: bus segment error
PROFIsafe: MD: bus segment error
Siemens SINUMERIK alarm 27201: PROFIsafe: MD []: bus segment error. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 27201 fires when an invalid bus segment value is configured in PROFIsafe-related machine data (MD) parameters. The SINUMERIK 840D expects bus segment MD value to be set to 5 for proper PROFIsafe communication; any other value triggers this alarm during NCK initialization or PROFIsafe handshake.
Safety
Causes and Fixes
Access Diagnostics menu on SINUMERIK 840D: Press [Diagnostics] → [Machine Data] → [Safety] or navigate via HMI to find PROFIsafe-related MD parameters.
Locate the bus segment MD parameter referenced in alarm message %1[%2]. Cross-reference with machine documentation to identify the exact MD number (typically MD 37xxx or MD 38xxx range for safety parameters).
Note the complete MD parameter name and index from the alarm display (%1 and %2 fields).
Verify current value and change it to 5. Edit the MD parameter using [Edit] or [Modify] function, then press [Enter] to confirm the change to value 5.
Do not modify other safety-related MD parameters simultaneously; change only the bus segment value.
Execute NCK reset: Press [Reset] on control panel or use HMI Reset function to reinitialize the system and validate the new MD value.