Safety · Intermediate · 30-120 minutes
Siemens 840D 27202 - PROFIsafe: MD: address error
Alarm 27202 is triggered when a PROFIsafe address parameter in machine data is configured with an invalid value—typically zero or negative—which violates the PROFIsafe protocol requirement that all safety-relevant addresses must be positive integers. This commonly occurs during initial machine data setup or after incorrect parameter edits in the NCK/PLC configuration menus.
Siemens 840D 27202 - PROFIsafe: MD: address error
PROFIsafe: MD: address error
Siemens SINUMERIK alarm 27202: PROFIsafe: MD []: address error. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
Alarm 27202 is triggered when a PROFIsafe address parameter in machine data is configured with an invalid value—typically zero or negative—which violates the PROFIsafe protocol requirement that all safety-relevant addresses must be positive integers. This commonly occurs during initial machine data setup or after incorrect parameter edits in the NCK/PLC configuration menus.
Safety
Causes and Fixes
Navigate to Diagnostics > Machine Data in the HMI and search for the specific MD parameter referenced in the alarm message (check the %1 and %3 values in the alarm text).
Verify the current value is not 0 or negative. Cross-reference against the machine safety documentation and PROFIsafe device configuration to confirm the correct positive address range (typically 1–2047 depending on PROFIsafe slot assignment).
Do not modify safety-critical parameters without authorization; consult machine safety validation documentation first.
Edit the parameter to the correct positive value using Siemens Automation Tool (SAT) or direct HMI parameter entry, then perform a 'Save and Compile' operation from the NCK parameter menu.
Perform a warm restart (Ctrl+Shift+Del or equivalent) or full NCK reboot to reload machine data and clear the alarm.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.