Siemens SINUMERIK Controller
Servo/Axis · Intermediate · 30-120 minutes
Siemens 27103 - Axis difference in function safe limit position , NCK: drive:
Alarm 27103 indicates a discrepancy between NCK (Numerical Control Kernel) and drive monitoring channels during safe limit position (SLP) cross-comparison in result list 1. This dual-channel monitoring mismatch compromises functional safety integrity and requires immediate diagnostic intervention to identify which channel has failed.
Siemens 27103 - Axis difference in function safe limit position , NCK: drive:
Axis difference in function safe limit position, NCK: drive
During cross-comparison of result list 1 a difference was detected between the NCK and drive monitoring channels in the status of safe limit position monitoring. - Safe limit position 1: Bit 2, 3 in result list 1 - Safe limit position 2: Bit 4, 5 in result list 1 Monitoring status (,): - OFF = Monitoring is inactive in this monitoring channel - OK = Monitoring is active in this monitoring channel, limit values are not violated - L+ = Monitoring is active in this monitoring channel, upper limit exceeded - L- = Monitoring is active in this monitoring channel, lower limit exceeded Control reaction: NC Start disable in this channel. Alarm display. A Stop F was triggered. If safe monitoring was active, STOP B was also triggered automatically. In this case, a power OFF/ON of the control will be required. Alarms.
Root Cause Summary
Alarm 27103 indicates a discrepancy between NCK (Numerical Control Kernel) and drive monitoring channels during safe limit position (SLP) cross-comparison in result list 1. This dual-channel monitoring mismatch compromises functional safety integrity and requires immediate diagnostic intervention to identify which channel has failed.
Safety
Causes and Fixes
Access Diagnostics > Axis > [Axis %1] > Result List 1 in HMI/SINUMERIK Operate. Document the exact bit states for bits 2-5 on both NCK and DRIVE channels to confirm which is reporting OFF/failed state.
Do not clear alarms until root cause is identified; clearing may mask intermittent safety channel failures.
Verify drive encoder connection and signal integrity using Diagnostics > Drives > [Drive] > Encoder feedback. Check MD30110 (encoder type) and MD30111 (encoder resolution) parameters match hardware configuration.
Loss of encoder signal immediately disables safe limit monitoring on drive side.
Download and compare drive firmware version against your machine documentation. If discrepancy found, perform drive firmware update via STARTER software with power-down cycle.
Interrupt power during firmware update can corrupt safety module; use UPS-backed startup procedure.
If encoder and firmware are verified, perform hardware replacement of servo drive or safety relay module and re-initialize SLP parameters via MD32700-MD32799 range (safe limit position monitoring setup).
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.