axismd.ai
Siemens SINUMERIK Controller
Servo/Axis · Advanced · 30 - 90 min
Siemens 25110 - Axis selected encoder not available
SIEMENS alarm 25110 DRIVE-CLiQ Fault occurs when communication between DRIVE-CLiQ components (Control Unit, Motor Modules, Sensor Modules) is disrupted or lost. This typically results from loose connections, damaged cables, component failures, or electromagnetic interference affecting the DRIVE-CLiQ topology.
Siemens 25110 - Axis selected encoder not available
Axis selected encoder not available
The selected encoder does not correspond to the maximum number of encoders in the axis-specific MD30200 $MA_NUM_ENCS, i.e. the 2nd encoder does not exist Control reaction: Alarm display.
Root Cause Summary
SIEMENS alarm 25110 DRIVE-CLiQ Fault occurs when communication between DRIVE-CLiQ components (Control Unit, Motor Modules, Sensor Modules) is disrupted or lost. This typically results from loose connections, damaged cables, component failures, or electromagnetic interference affecting the DRIVE-CLiQ topology.
Safety
Causes and Fixes
Power Down System Safely
Navigate to HMI → Machine → Switch Off, wait for all drives to reach standstill, then disconnect 24V DC supply.
Never disconnect DRIVE-CLiQ cables under power - this can damage components
Inspect DRIVE-CLiQ Cable Connections
Check all green DRIVE-CLiQ connectors on Control Unit CU320-2 and Motor Modules for proper seating, damaged pins, or contamination.
Look for the green locking tabs - they should click audibly when properly seated
Verify Cable Integrity
Examine DRIVE-CLiQ cables for kinks, cuts, or excessive bending near connectors. Replace any damaged cables with genuine Siemens parts.
DRIVE-CLiQ cables have minimum bend radius requirements - maintain at least 5x cable diameter
Test Communication
Power up system and check HMI → Diagnostics → Hardware → DRIVE-CLiQ topology display to verify all components are recognized.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.