Siemens SINUMERIK codes
Siemens SINUMERIKServo/AxisAdvanced1 - 4 hours

25100

Siemens 25100 - Axis measuring system switchover not possible

Axis measuring system switchover not possible

Siemens SINUMERIK alarm 25100: Axis measuring system switchover not possible. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SINUMERIK alarm 25100 occurs when the DC link voltage in the drive system exceeds the maximum threshold, typically 820V for 400V systems. This commonly happens during rapid deceleration when regenerative braking energy cannot be properly dissipated through the brake resistor or when the power supply voltage is too high.

Safety

  • Drive/power/encoder circuit: hazardous voltages may remain in the DC link after power-off. Lock out / tag out, wait for discharge per the drive documentation, and use qualified personnel only.

Causes and Fixes

  1. 1

    Check Brake Resistor Status

    Navigate to HMI > Diagnostics > Drive > Power Module and check brake resistor status. Verify parameter P1237 (brake resistor resistance value) matches actual resistor specification.

    Use a multimeter to measure actual brake resistor resistance when drive is powered down - should match P1237 value within 10%

  2. 2

    Verify Brake Chopper Operation

    Check parameter P1215 (brake chopper enable) is set to 1. Monitor r0026 (DC link voltage) and r1242 (brake chopper utilization) during deceleration moves.

    Never disconnect brake resistor wiring while system is powered - risk of drive damage

  3. 3

    Inspect Brake Circuit Wiring

    Power down system and check brake resistor connections at terminals +BR and -BR on power module. Verify cable integrity and proper torque specifications per drive manual.

    Look for discoloration or burning around brake resistor terminals - indicates overheating

DIY Feasiblehigh confidence

Call a technician if:

  • ·Brake resistor replacement required
  • ·DC link capacitor replacement needed
  • ·Input voltage regulation installation required

Prevention

  • Monitor brake resistor utilization regularly via r1242
  • Implement gradual deceleration ramps in part programs
  • Schedule preventive capacitor replacement every 5-7 years
  • Install AC line reactors in electrically noisy environments

Common Mistakes

  • Ignoring brake resistor temperature ratings
  • Setting deceleration ramps too aggressively
  • Bypassing brake resistor safety circuits
  • Using incorrect brake resistor resistance values in P1237

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.