Siemens SINUMERIK codes
Siemens SINUMERIKPower SupplyIntermediate15-45 minutes

2110

Siemens Alarm 2110 - NCK Battery Dead

Battery Failure

Siemens SINUMERIK alarm 2110: Battery Failure. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.

Root Cause Summary

SINUMERIK alarm 2110 indicates the NCK has detected corrupted or defective SRAM memory during the power-on memory test. This hardware fault typically results from battery failure, memory module degradation, or electrical interference affecting the NCU's volatile memory integrity.

Safety

  • Data loss imminent
  • Do not power off

Causes and Fixes

  1. 1

    Check Battery Status

    Navigate to HMI > Diagnostics > Hardware > NCU and check battery voltage display. Normal voltage should be 3.4-3.8V.

    Battery voltage below 3.2V will trigger memory corruption even if system appears functional.

  2. 2

    Replace NCU Battery

    Power down system completely, replace lithium battery (typically CR2032 or equivalent) on NCU module following proper ESD procedures.

    Always power down NCU before battery replacement to prevent data corruption.

  3. 3

    Restore Machine Data

    After battery replacement, restore machine data from backup archive via HMI > Commissioning > Data Backup/Restore or load INI files from CF card.

    Always verify MD11210 (memory test enable) is set to 1 after data restoration.

  4. 4

    Perform Memory Test

    Execute complete SRAM test via HMI > Diagnostics > Memory Test or set MD11200 to force extended memory check on next startup.

Service Recommendedmedium confidence

Call a technician if:

  • ·NCU replacement required
  • ·Multiple hardware faults detected
  • ·Repeated alarm after battery replacement
  • ·Power supply modifications needed

Prevention

  • Replace NCU battery every 3-5 years
  • Maintain clean 24VDC power supply
  • Perform regular system backups
  • Monitor battery voltage monthly
  • Ensure proper cabinet grounding

Common Mistakes

  • Ignoring battery voltage warnings
  • Attempting NCU repair instead of replacement
  • Not backing up data before troubleshooting
  • Replacing battery with system powered on
  • Using non-Siemens approved replacement parts

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.