Siemens Alarm 2110 - NCK Battery Dead
SINUMERIK alarm 2110 indicates the NCK has detected corrupted or defective SRAM memory during the power-on memory test. This hardware fault typically results from battery failure, memory module degradation, or electrical interference affecting the NCU's volatile memory integrity.
Siemens Alarm 2110 - NCK Battery Dead
Battery Failure
Siemens SINUMERIK alarm 2110: Battery Failure. This alarm indicates a fault or error condition on the SINUMERIK 840D control. Refer to the Siemens SINUMERIK alarm documentation for the complete description and remedy.
Root Cause Summary
SINUMERIK alarm 2110 indicates the NCK has detected corrupted or defective SRAM memory during the power-on memory test. This hardware fault typically results from battery failure, memory module degradation, or electrical interference affecting the NCU's volatile memory integrity.
Safety
Causes and Fixes
Check Battery Status
Navigate to HMI > Diagnostics > Hardware > NCU and check battery voltage display. Normal voltage should be 3.4-3.8V.
Battery voltage below 3.2V will trigger memory corruption even if system appears functional.
Replace NCU Battery
Power down system completely, replace lithium battery (typically CR2032 or equivalent) on NCU module following proper ESD procedures.
Always power down NCU before battery replacement to prevent data corruption.
Restore Machine Data
After battery replacement, restore machine data from backup archive via HMI > Commissioning > Data Backup/Restore or load INI files from CF card.
Always verify MD11210 (memory test enable) is set to 1 after data restoration.
Perform Memory Test
Execute complete SRAM test via HMI > Diagnostics > Memory Test or set MD11200 to force extended memory check on next startup.
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.