Siemens 17630 - Block referencing for transformed axis not possible
In the displayed block, an axis is programmed for reference point approach (G74) that is involved in the active transformation. Reference point approach is not performed with this axis! Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.
Siemens 17630 - Block referencing for transformed axis not possible
Block referencing for transformed axis not possible
In the displayed block, an axis is programmed for reference point approach (G74) that is involved in the active transformation. Reference point approach is not performed with this axis! Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.