Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeBasic5 - 15 minutes

18002

Siemens 18002 - Block NCK protection zone cannot be activated. Error code

Block NCK protection zone cannot be activated. Error code

Siemens SINUMERIK alarm 18002: Block NCK protection zone cannot be activated. Error code. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SIEMENS alarm 18002 'Coolant Level Low' is triggered when the coolant level sensor detects insufficient coolant in the reservoir tank. This alarm is generated through the PLC interface monitoring the coolant system status via digital input signals configured in the machine data parameters.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Physical Coolant Level

    Visually inspect the coolant reservoir tank to verify actual coolant level against the sensor position.

    Ensure machine is in safe state before opening coolant tank covers

  2. 2

    Verify Sensor Operation

    Navigate to Diagnostics > PLC > Inputs/Outputs to check the coolant level sensor input status (typically DB31.DBX or similar PLC interface).

    Compare sensor reading with visual inspection to confirm sensor accuracy

  3. 3

    Refill Coolant System

    Add appropriate coolant mixture to reservoir tank, ensuring proper concentration ratio as specified in machine documentation.

    Use only manufacturer-approved coolant types to prevent system damage

  4. 4

    Reset Alarm

    Press RESET key or navigate to Alarms > Reset to clear the alarm after coolant level is restored.

    Monitor for alarm recurrence which may indicate leakage or consumption issues

DIY Feasiblehigh confidence

Call a technician if:

  • ·Sensor replacement requires electrical work beyond operator skill level
  • ·Internal spindle coolant leaks detected
  • ·PLC configuration changes needed beyond basic parameters

Prevention

  • Establish daily coolant level checks in operator routine
  • Implement preventive coolant system maintenance schedule
  • Monitor coolant consumption trends to detect developing leaks
  • Replace coolant filters on recommended intervals

Common Mistakes

  • Ignoring recurring alarms after refilling without investigating root cause
  • Using incorrect coolant concentration ratios
  • Forcing alarm reset without verifying actual coolant level
  • Neglecting to check sensor calibration during maintenance

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free