Siemens SINUMERIK codes
Siemens SINUMERIKToolIntermediate15-30 minutes

20001

Siemens 20001 - Axis no cam signal present

Axis no cam signal present

Siemens SINUMERIK alarm 20001: Axis no cam signal present. Detailed remedy is being verified against the current Siemens diagnostics manual.

Root Cause Summary

SIEMENS alarm 20001 occurs when the NC controller fails to receive the tool clamped confirmation signal from the PLC within the monitoring time window defined in MD11420 (TOOL_CLAMP_TIME). The alarm triggers when the drawbar proximity sensor signal mapped to the PLC input does not activate or drops out during tool clamping operations.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Sensor Signal in PLC Diagnostics

    Navigate to Diagnostics > PLC > I/O Status and monitor the tool clamped input signal while manually actuating the drawbar. Verify signal changes state.

    Use HMI Service screen 'PLC Status' to view real-time I/O without entering service mode.

  2. 2

    Inspect Sensor Physical Condition

    Check proximity sensor for contamination, damage, or incorrect gap distance. Clean sensor face and verify 1-2mm gap to target when drawbar is fully retracted.

    Ensure spindle is stopped and locked out before accessing sensor area.

  3. 3

    Verify Sensor Power and Wiring

    Measure 24VDC supply voltage at sensor connector and check continuity of signal wire to PLC input terminal using multimeter.

    Check PLC input LED status - should illuminate when sensor activates.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Hydraulic system repairs required
  • ·PLC program modifications needed
  • ·Spindle mechanical rebuild necessary

Prevention

  • Regular proximity sensor cleaning
  • Periodic tool holder inspection and cleaning
  • Monitor hydraulic pressure trends
  • Verify MD11420 setting after spindle maintenance

Common Mistakes

  • Setting MD11420 too high masking mechanical issues
  • Ignoring intermittent sensor signals
  • Not checking tool holder pull stud condition
  • Forcing interface signals without fixing root cause

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.