Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

17900

Siemens 17900 - Block motion synchronous action: axis is not a machine axis

Block motion synchronous action: axis is not a machine axis

At this point, the block context calls for a machine axis. This is the case with: - G74 (reference point approach) - G75 (fixed point approach) If a geometry or additional axis identifier is used, then it must also be allowed as machine axis identifier (MD10000 $MN_AXCONF_MACHAX_NAME_TAB) Control reaction: NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • At this point, the block context calls for a machine axis.
  • This is the case with: - G74 (reference point approach) - G75 (fixed point approach) If a geometry or additional axis identifier is used, then it must also be allowed as machine axis identifier (MD10000 $MN_AXCONF_MACHAX_NAME_TAB)

Troubleshooting Steps

  1. 1Use machine axis identifier when programming.
  2. 2Clear alarm with the RESET key. Restart part program Continuation: Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.