Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

15400

Siemens 15400 - Block selected initial INIT block does not exist

Block selected initial INIT block does not exist

The operator has selected an INI block for a read, write or execution function which: 1. Does not exist in the NCK range or 2. Does not have the necessary protection level required for performing the function Control reaction: Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The operator has selected an INI block for a read, write or execution function which: 1.
  • Does not exist in the NCK range or 2.
  • Does not have the necessary protection level required for performing the function

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2Check whether the selected INI block is contained in the file system of the NCK.
  3. 3The present protection level must be selected to be at least equal to (or greater than) the protection level that has been defined for the read, write or execution function at the time of creating the file.
  4. 4Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.