Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeBasic10-20 minutes

15410

Siemens 15410 - Block initialization file contains invalid M function

Block initialization file contains invalid M function

The only M function allowed in an Init block is the M02, M17 or M30 end-of-program function Control reaction: Interpreter stop NC Start disable in this channel. Interface signals are set. Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The only M function allowed in an Init block is the M02, M17 or M30 end-of-program function

Troubleshooting Steps

  1. 1Remove all M functions from the Init block except for the end identifier.
  2. 2An Init block may contain value assignments only (and global data definitions if they are not defined again in a program that can be executed later) but no motion or synchronous actions.
  3. 3Clear alarm with the RESET key. Restart part program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.