Siemens SINUMERIK Controller
Program/G-code · Intermediate · 15-60 minutes
Siemens 14010 - Block invalid default parameter in subroutine call
SINUMERIK alarm 14010 fires when the NCK interpreter encounters a G-code that is not defined in the current system configuration, typically due to missing software options, incorrect post-processor settings, or unsupported G-codes for the active control version. The alarm triggers during block preparation phase before any machine movement occurs.
Siemens 14010 - Block invalid default parameter in subroutine call
Block invalid default parameter in subroutine call
In a subroutine call with parameter transfer, parameters have been omitted that cannot be replaced by default parameters (call-by-reference parameters or parameters of type AXIS. The other missing parameters are defaulted with the value 0 or with the unit frame in the case of frames) Control reaction: Correction block is reorganized. Interface signals are set. Alarm display.
Root Cause Summary
SINUMERIK alarm 14010 fires when the NCK interpreter encounters a G-code that is not defined in the current system configuration, typically due to missing software options, incorrect post-processor settings, or unsupported G-codes for the active control version. The alarm triggers during block preparation phase before any machine movement occurs.
Safety
Causes and Fixes
Check Active Software Options
Navigate to HMI → Diagnostics → Service → Software options and verify which packages are installed and licensed.
Compare the required G-code against the software option list - threading cycles need 'Advanced Surface' package
Verify G-Code Requirements
Cross-reference the undefined G-code in SINUMERIK Programming Guide to determine which software option package is required.
G150-G159 polynomial interpolation requires 'Advanced Surface' option, G331/G332 need 'Cycles' package
Contact Siemens for License Upgrade
If required option is missing, contact Siemens or authorized dealer to purchase and install the necessary software license.
Never attempt to bypass software licensing - this violates terms of service
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.