Siemens 10914 - Block : movement not possible while transformation active.
The machine kinematics does not allow the specified motion. Transformation-dependent error causes can be in: TRANSMIT: A (circular) area exists around the pole, where positioning is not possible. The area is caused by the fact that the tool reference point cannot be traversed as far as into the pole. The area is defined by: - the machine data (MD24920 $MC_TRANSMIT_BASE_TOOL.) - the active tool length compensation (see $TC_DP.). Whether the tool length compensation is included in the calculation depends on the working plane selected (see G17,.). - The machine stops before the faulty block Control reaction: Interpreter stop Local alarm reaction. NC Start disable in this channel. Interface signals are set. Alarm display.
Siemens 10914 - Block : movement not possible while transformation active.
Block: movement not possible while transformation active.
The machine kinematics does not allow the specified motion. Transformation-dependent error causes can be in: TRANSMIT: A (circular) area exists around the pole, where positioning is not possible. The area is caused by the fact that the tool reference point cannot be traversed as far as into the pole. The area is defined by: - the machine data (MD24920 $MC_TRANSMIT_BASE_TOOL.) - the active tool length compensation (see $TC_DP.). Whether the tool length compensation is included in the calculation depends on the working plane selected (see G17,.). - The machine stops before the faulty block Control reaction: Interpreter stop Local alarm reaction. NC Start disable in this channel. Interface signals are set. Alarm display.
Safety
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.