Siemens 10778 - Block preprocessing stop with active tool radius compensation
If a preprocessing stop is detected with active tool radius compensation (either programmed by the user or generated internally) and the SD42480 $SC_STOP_CUTCOM_STOPRE is set, then this warning is issued because in this situation machine movements which were not intended by the user can occur (termination of radius compensation and new approach) Control reaction: Alarm display. NC Stop on alarm at block end.
Siemens 10778 - Block preprocessing stop with active tool radius compensation
Block preprocessing stop with active tool radius compensation
If a preprocessing stop is detected with active tool radius compensation (either programmed by the user or generated internally) and the SD42480 $SC_STOP_CUTCOM_STOPRE is set, then this warning is issued because in this situation machine movements which were not intended by the user can occur (termination of radius compensation and new approach) Control reaction: Alarm display. NC Stop on alarm at block end.
Safety
Common Causes
Troubleshooting Steps
Seeing Multiple Alarms?