Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

10777

Siemens 10777 - Block tool radius compensation: too many blocks with suppression

Block tool radius compensation: too many blocks with suppression

The maximum permissible number of blocks with active compensation suppression with tool radius compensation is limited by MD20252 $MC_CUTCOM_MAXNUM_SUPPR_BLOCKS Control reaction: Correction block is reorganized. Local alarm reaction. Interface signals are set. Alarm display. NC Stop on alarm at block end.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The maximum permissible number of blocks with active compensation suppression with tool radius compensation is limited by MD20252 $MC_CUTCOM_MAXNUM_SUPPR_BLOCKS

Troubleshooting Steps

  1. 1Modify part program.
  2. 2Modify machine data.
  3. 3Check whether SBL2 is activated.
  4. 4With SBL2, a block is generated from each part program line which can lead to exceeding the maximum permissible number of empty blocks between two traversing blocks.
  5. 5Clear alarm with NC START or RESET key and continue the program

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.