Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

10654

Siemens 10654 - Waiting for synchronization start of gantry group

Waiting for synchronization start of gantry group

The alarm message appears when the axes are ready for synchronization. The gantry grouping can now be synchronized. The actual value difference between the master and slave axes is greater than the gantry warning limit MD 37110 $MA_GANTRY_POS_TOL_WARNING. The synchronization must be started explicitly with the NC/PLC interface signal DB31,. DBX29.4 (Start gantry synchronization) Control reaction: Alarm display.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • The alarm message appears when the axes are ready for synchronization.
  • The gantry grouping can now be synchronized.
  • The actual value difference between the master and slave axes is greater than the gantry warning limit MD 37110 $MA_GANTRY_POS_TOL_WARNING.

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 2See Function Manual, Special Functions, Gantry Axes (G1)
  3. 3Alarm display showing cause of alarm disappears. No further operator action necessary

Seeing Multiple Alarms?