Siemens 10657 - Axis power OFF in the gantry error limit exceeded status

Axis power OFF in the gantry error limit exceeded status

Gantry error limit exceeded status (alarm 10653) has been switched off. The error can only be removed by deleting MD37135 $MA_GANTRY_ACT_POS_TOL_ERROR or by deactivating the extended monitoring (MD37150 $MA_GANTRY_FUNCTION_MASK Bit0) Control reaction: NC Start disable in this channel. Interface signals are set. Alarm display. NC Stop on alarm.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Common Causes

  • Gantry error limit exceeded status (alarm 10653) has been switched off.
  • The error can only be removed by deleting MD37135 $MA_GANTRY_ACT_POS_TOL_ERROR or by deactivating the extended monitoring (MD37150 $MA_GANTRY_FUNCTION_MASK Bit0)

Troubleshooting Steps

  1. 1Please inform the authorized personnel/service department.
  2. 21.
  3. 3Remove a mechanical misalignment 2.
  4. 4Check axis (uneven mechanical movement?) 3.
  5. 5Delete MD37135 $MA_GANTRY_ACT_POS_TOL_ERROR or deactivate the extended monitoring 4.
  6. 6MD37120 $MA_GANTRY_POS_TOL_ERROR is set incorrectly If the MD is changed, a Power ON will be required.
  7. 7Clear alarm with the RESET key. Restart part program