10605

Siemens 10605 - Block thread pitch decrease too high

Block thread pitch decrease too high

The thread pitch decrease is causing an axis standstill in the thread block Control reaction: Correction block is reorganized. Local alarm reaction. Interface signals are set. Alarm display.

Root Cause Summary

SINUMERIK alarm 10605 occurs when the Z-axis physically contacts the positive hardware limit switch, triggering an immediate emergency stop. This hardware interlock is activated by machine data parameter MD36100 (POS_LIMIT_SWITCH) and prevents mechanical damage to the machine structure.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Check Active Work Offset

    Press OFFSET key, navigate to Work Offset tab, verify G54-G59 Z-axis values against machine coordinate system using MD26010 (G54_X), MD26020 (G54_Y), MD26030 (G54_Z).

    Use machine coordinate display (MCS) to verify actual position relative to machine zero

  2. 2

    Verify Tool Length Compensation

    Check Tool Management, verify active tool length offset T-number corresponds to correct geometry offset D-number in tool table parameters.

    Excessive positive tool length values can cause virtual overtravel

  3. 3

    Validate Program Coordinates

    Review NC program for Z-axis moves, calculate total travel including work offset + tool length + programmed coordinate against MD36200 (SOFTWARE_LIMIT_PLUS_Z).

    Use SINUMERIK simulation mode to trace axis movements before execution

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder feedback errors persist
  • ·Machine data parameter corruption
  • ·Mechanical damage to limit switches or actuators

Prevention

  • Regular verification of work offset accuracy
  • Implement program simulation before execution
  • Periodic limit switch function testing
  • Maintain proper reference point procedures

Common Mistakes

  • Ignoring software limit warnings before hardware activation
  • Incorrect tool length measurement entry
  • Modifying machine data without understanding coordinate relationships
  • Forcing jog movement while on limit switch

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.