10604

Siemens 10604 - Block thread pitch increase too high

Block thread pitch increase too high

The thread pitch increase is causing an axis overload. A spindle override of 100 is assumed during verification Control reaction: Correction block is reorganized. Local alarm reaction. Interface signals are set. Alarm display.

Root Cause Summary

Alarm 10604 occurs when SINAMICS drive modules fail to reach ready state within the NCK timeout period, preventing servo enable release. This typically results from drive hardware faults, communication disruptions between NCK and drive units, or incorrect drive configuration parameters in the SINUMERIK system.

Safety

  • Spindle hazard: ensure the spindle is at standstill before working near it; follow lockout/tagout procedures.

Causes and Fixes

  1. 1

    Check Drive LED Status

    Examine SINAMICS drive module LEDs - red LED indicates fault condition, yellow indicates not ready state.

    Ensure EMERGENCY STOP is active before accessing drive cabinet

  2. 2

    Access SINAMICS Diagnostics

    Navigate to Diagnostics > Drive Diagnosis in HMI, check fault buffer for specific drive fault codes (F-codes) or alarms (A-codes).

    F30001 (Infeed fault) and F30005 (Motor overtemperature) are common causes

  3. 3

    Verify Drive Power Supply

    Check 24VDC control voltage and main power supply voltages to SINAMICS units using multimeter at X122 terminals.

    Use proper PPE and lockout procedures when measuring voltages

  4. 4

    Reset Drive Faults

    Use STARTER software or HMI Diagnostics menu to acknowledge and reset drive faults, then attempt servo enable.

    Some faults require power cycle of drive unit after acknowledgment

DIY Feasiblehigh confidence

Call a technician if:

  • ·Drive hardware replacement required
  • ·Complex PROFINET configuration issues
  • ·Safety circuit modifications needed

Prevention

  • Regular inspection of drive cabinet cooling and air filters
  • Periodic PROFIBUS/PROFINET cable inspection
  • Maintain proper environmental conditions per SINAMICS specifications
  • Regular backup of NCK machine data and drive parameters

Common Mistakes

  • Ignoring drive fault buffer before troubleshooting 10604
  • Changing multiple machine data parameters simultaneously
  • Not verifying bus termination after cable repairs
  • Attempting servo enable with active safety circuits

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.