Siemens SINUMERIK codes
Siemens SINUMERIKCommunicationIntermediate30-120 minutes

10222

Siemens 10222 - Inter-channel communication not possible

Inter-channel communication not possible

This channel has received a negative acknowledgment from the inter-channel communication because the destination channel number is not known, e.g.: START(x) or WAITE(x) but channel x has not been initialized Control reaction: Alarm display.

Root Cause Summary

Alarm 10222 occurs when synchronization or communication between multiple channels in a multi-channel system fails. This typically happens when WAIT MARKG or GET synchronization commands cannot establish proper inter-channel communication, often due to syntax errors, channel configuration mismatches, or blocked channel states preventing the handshake.

Safety

  • Only qualified personnel should diagnose and clear control alarms; follow the machine builder's safety procedures and lockout/tagout where hardware work is required.

Causes and Fixes

  1. 1

    Review the NC program at the alarm location and identify all WAIT MARKG and GET commands with their channel references.

  2. 2

    Verify that each WAIT MARKG in one channel has a corresponding GET command in the target channel with matching marker identifiers and correct channel numbers.

  3. 3

    Check that the channel identifier syntax is correct (e.g., WAITM(2,1) waits for channel 2, marker 1) and matches your actual channel configuration.

  4. 4

    Correct any syntax errors or mismatched pairs, ensure both channels reach their synchronization points, then reset the alarm and restart the program.

Service Recommended confidence