Siemens 10222 - Inter-channel communication not possible
Alarm 10222 occurs when synchronization or communication between multiple channels in a multi-channel system fails. This typically happens when WAIT MARKG or GET synchronization commands cannot establish proper inter-channel communication, often due to syntax errors, channel configuration mismatches, or blocked channel states preventing the handshake.
Siemens 10222 - Inter-channel communication not possible
Inter-channel communication not possible
This channel has received a negative acknowledgment from the inter-channel communication because the destination channel number is not known, e.g.: START(x) or WAITE(x) but channel x has not been initialized Control reaction: Alarm display.
Root Cause Summary
Alarm 10222 occurs when synchronization or communication between multiple channels in a multi-channel system fails. This typically happens when WAIT MARKG or GET synchronization commands cannot establish proper inter-channel communication, often due to syntax errors, channel configuration mismatches, or blocked channel states preventing the handshake.
Safety
Causes and Fixes
Review the NC program at the alarm location and identify all WAIT MARKG and GET commands with their channel references.
Verify that each WAIT MARKG in one channel has a corresponding GET command in the target channel with matching marker identifiers and correct channel numbers.
Check that the channel identifier syntax is correct (e.g., WAITM(2,1) waits for channel 2, marker 1) and matches your actual channel configuration.
Correct any syntax errors or mismatched pairs, ensure both channels reach their synchronization points, then reset the alarm and restart the program.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.