Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

101632

Siemens 840D 101632 - Write access only in start-up state Parameter Reset (p10=30).

Write access only in start-up state Parameter Reset (p10=30).

Siemens SINUMERIK operator message 101632: Write access only in start-up state Parameter Reset (p10=30). This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.

Root Cause Summary

This alarm occurs when attempting to modify write-protected system parameters or machine data during normal operation mode. These critical parameters can only be changed when the control is in start-up mode with Parameter Reset active (protection level 10=30), which is a safety feature to prevent accidental changes during production.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Press the NCK RESET button or perform a power-on reset to enter start-up state

    This will interrupt current operations - ensure machine is safe and no programs are running

  2. 2

    Navigate to Commissioning mode: Press MENU SELECT → Commissioning → Set protection level 10 = 30 (Parameter Reset)

    Requires password level 2 (Service) or higher access rights

  3. 3

    Make the required parameter changes to the specific machine data or setting data

  4. 4

    Perform NCK RESET to activate changes and return to normal operation mode

    All changes take effect after reset - verify machine behavior after restart

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.