axismd.ai
Siemens SINUMERIK Controller
Program/G-code · Intermediate · 30-120 minutes
Siemens 840D 101636 - Write access only in start-up state Download (p10=29).
Alarm 101636 indicates an attempt to modify protected system data or parameters that can only be changed when the control is in the specific start-up state Download (p10=29). This alarm occurs when write operations are attempted in normal operating mode on data reserved for commissioning or system configuration changes.
Siemens 840D 101636 - Write access only in start-up state Download (p10=29).
Write access only in start-up state Download (p10=29).
Siemens SINUMERIK operator message 101636: Write access only in start-up state Download (p10=29). This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.
Root Cause Summary
Alarm 101636 indicates an attempt to modify protected system data or parameters that can only be changed when the control is in the specific start-up state Download (p10=29). This alarm occurs when write operations are attempted in normal operating mode on data reserved for commissioning or system configuration changes.
Safety
Causes and Fixes
Press RECALL key, then select 'Start-up' from the operating area menu
Navigate to 'Special functions' and set switch p10 to position 29 (Download mode)
This mode disables safety functions - ensure machine is in safe state and production is stopped
Perform the required parameter write or configuration change
Reset p10 to normal operating position (0) and perform a control restart to activate changes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.