Siemens SINUMERIK codes
Siemens SINUMERIKProgram/G-codeIntermediate30-120 minutes

101619

Siemens 840D 101619 - Parameter currently deactivated.

Parameter currently deactivated.

Siemens SINUMERIK operator message 101619: Parameter currently deactivated. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.

Root Cause Summary

Alarm 101619 occurs when a part program or machine function attempts to use a parameter or setting that has been intentionally deactivated in the system configuration. This typically happens when optional functions are disabled in machine data, cycle parameters are not enabled, or specific technology packages have been deactivated by the machine builder or system administrator.

Safety

  • Refer to Siemens documentation
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check which NC block triggered the alarm and identify the G-code, cycle, or function being called (review alarm log for line number).

  2. 2

    Access machine data settings via HMI: Commissioning > Machine Data and search for the relevant setting bits related to the function (e.g., MD20110 for transformation options, MD18118 for cycle settings).

  3. 3

    Verify the license options installed on the NCU using Service > System Data > License Keys to confirm if the required technology package is licensed and active.

  4. 4

    If function should be available, activate the appropriate machine data bit or contact machine builder to enable the option; if not available, modify the part program to remove or replace the deactivated function.

    Changing machine data may affect machine behavior. Document original settings before modification and perform test runs.

Service Recommended confidence

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.