Siemens 840D 101622 - Value impermissible
Alarm 101622 'Value impermissible' occurs when a programmed parameter value violates the permissible range defined by the system or machine data. This typically happens with NC programming syntax errors, out-of-range axis positions, feed rates, spindle speeds, or tool parameters that exceed configured limits. The alarm is triggered during program compilation or execution when the control detects an invalid numerical value.
Siemens 840D 101622 - Value impermissible
Value impermissible
Siemens SINUMERIK operator message 101622: Value impermissible. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.
Root Cause Summary
Alarm 101622 'Value impermissible' occurs when a programmed parameter value violates the permissible range defined by the system or machine data. This typically happens with NC programming syntax errors, out-of-range axis positions, feed rates, spindle speeds, or tool parameters that exceed configured limits. The alarm is triggered during program compilation or execution when the control detects an invalid numerical value.
Safety
Causes and Fixes
Check the alarm detail display to identify the specific NC block number and parameter causing the error.
Verify the programmed axis values against software limit switches in MD36100 (Software_LIMIT_PLUS) and MD36110 (SOFT_LIMIT_MINUS) for each axis.
Check feedrate F value against maximum permitted feed MD32000 (MAX_AX_VELO) and spindle speed S against MD35100 (SPINDLE_MAX_SPEED_LIMS).
Correct the NC program value to fall within permissible ranges and reset the alarm using the NC Start button or RESET key.