Siemens 840D 101628 - Write access only in start-up state Motor (p10=3).
This alarm occurs when attempting to modify a write-protected motor parameter that can only be changed when the drive is in start-up mode (p10=3). The drive commissioning parameter p10 must be set to value 3 to enable write access to protected motor configuration parameters.
Siemens 840D 101628 - Write access only in start-up state Motor (p10=3).
Write access only in start-up state Motor (p10=3).
Siemens SINUMERIK operator message 101628: Write access only in start-up state Motor (p10=3). This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.
Root Cause Summary
This alarm occurs when attempting to modify a write-protected motor parameter that can only be changed when the drive is in start-up mode (p10=3). The drive commissioning parameter p10 must be set to value 3 to enable write access to protected motor configuration parameters.
Safety
Causes and Fixes
Access the drive system via STARTER or Scout commissioning software for the affected axis.
Navigate to parameter p10 (commissioning parameter) and verify current value. If p10=0 (normal operation), change to p10=3 (start-up mode).
Setting p10=3 disables drive enable - ensure machine is in safe state before proceeding
Modify the required motor parameter that triggered the alarm. Common protected parameters include p0304 (rated motor voltage), p0305 (rated motor current), p0307 (rated motor power), p0308-p0311 (motor connection type and ratings).
After parameter modification is complete, reset p10 back to p10=0 (normal operation) and perform a drive reset (POWER ON). Verify alarm clears and test axis movement.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.