axismd.ai
Siemens SINUMERIK Controller
Program/G-code · Intermediate · 30-120 minutes
Siemens 840D 101615 - Parameter address impermissible
Alarm 101615 occurs when the NC program contains an invalid or impermissible parameter address in a programming block. This typically happens when a parameter letter (address) is used incorrectly, duplicated, or not allowed in the current context or with the current G-code combination.
Siemens 840D 101615 - Parameter address impermissible
Parameter address impermissible
Siemens SINUMERIK operator message 101615: Parameter address impermissible. This is an informational message from the SINUMERIK control indicating a system status or operation result that may require operator action.
Root Cause Summary
Alarm 101615 occurs when the NC program contains an invalid or impermissible parameter address in a programming block. This typically happens when a parameter letter (address) is used incorrectly, duplicated, or not allowed in the current context or with the current G-code combination.
Safety
Causes and Fixes
Identify the NC block number from the alarm detail display on the HMI and locate it in the part program.
Check for duplicate addresses in the block (e.g., two X values, two F values) and remove the duplicate or split into separate blocks.
Verify that all addresses used are valid for the active G-code group (e.g., I, J, K only valid with G02/G03 circular interpolation).
Correct the NC program, reset the alarm, and test the program in single block mode.
Always backup the original program before making modifications.
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.