Okuma OSP Alarm D 4691 - MCS Rotary encoder 1 error
The MCS detected invalid data coming from Rotary encoder 1 on the indicated axis. The encoder reported an internal fault such as abnormal signal amplitude, an AD offset voltage problem, or a CPU error, so its position feedback can no longer be trusted.
Okuma OSP Alarm D 4691 - MCS Rotary encoder 1 error
MCS Rotary encoder 1 error
The MCS detected invalid data coming from Rotary encoder 1 on the indicated axis. The encoder reported an internal fault such as abnormal signal amplitude, an AD offset voltage problem, or a CPU error, so its position feedback can no longer be trusted.