KUKA Robot KRC0212 - ACKN BUS VOLTAGE CHARGING UNIT IS DEFECTIVE <KPS number>
This alarm indicates a failure in the ACKN (acknowledge) bus voltage charging unit, specifically that the optocoupler circuit on the KPS (KUKA Power Supply) module is not detecting current flow through the charging circuit. This typically occurs during the power-up sequence when the controller attempts to verify proper charging unit functionality before enabling the main servo drives.
KUKA Robot KRC0212 - ACKN BUS VOLTAGE CHARGING UNIT IS DEFECTIVE <KPS number>
ACKN BUS VOLTAGE CHARGING UNIT IS DEFECTIVE <KPS number>
This alarm indicates a failure in the ACKN (acknowledge) bus voltage charging unit, specifically that the optocoupler circuit on the KPS (KUKA Power Supply) module is not detecting current flow through the charging circuit. This typically occurs during the power-up sequence when the controller attempts to verify proper charging unit functionality before enabling the main servo drives.
Common Causes
Troubleshooting Steps