Heidenhain codes
HeidenhainSpindleIntermediate30-120 minutes

905-274D

Heidenhain 905-274D - Define the tool

Define the tool

Heidenhain TNC error 905-274D: Define the tool. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

HEIDENHAIN alarm 905-274D 'Define the tool' occurs when the TNC control requires tool definition data that is missing or incomplete in the tool table. This typically happens when attempting to execute a machining cycle or tool call without proper tool geometry or compensation values defined in the TOOL.T table.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Tool Table

    Press TOOL TABLE softkey, then select TOOL.T to open the tool definition table.

    Use Ctrl+F to quickly search for specific tool numbers in large tool tables

  2. 2

    Verify Tool Entry

    Check if the called tool number exists and has entries for LENGTH (L) and RADIUS (R) columns with non-zero values.

    Never enter negative values for tool radius as this will cause calculation errors

  3. 3

    Define Missing Tool Data

    Enter tool length, radius, and tool type (TYPE column) for the missing tool. Set NAME field for identification.

    Use tool type 'MILL' for end mills, 'DRILL' for drills, and 'TAP' for tapping tools

  4. 4

    Save and Test

    Press END key to save changes, then test the tool call in MDI mode using T[tool number] M6 command.

DIY Feasiblehigh confidence

Call a technician if:

  • ·Tool table corruption persists after restoration attempts
  • ·Machine parameter modifications required
  • ·Hardware tool changer communication errors

Prevention

  • Regularly backup TOOL.T table
  • Validate tool definitions before program execution
  • Use consistent tool numbering system
  • Perform tool table integrity checks during maintenance

Common Mistakes

  • Entering diameter instead of radius
  • Using tool numbers outside valid range
  • Forgetting to save tool table changes
  • Not defining tool type parameter

Related Alarms

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.