Heidenhain 905-2772 - End position Z

End position Z

Heidenhain TNC error 905-2772: End position Z. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

HEIDENHAIN alarm 905-2772 'End position Z' indicates the Z-axis has reached or exceeded its software or hardware travel limit during positioning or swing operation. This servo alarm typically occurs when the axis position exceeds the defined working envelope parameters or encounters mechanical interference.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Check current Z position

    Press POS key and verify actual Z position against machine coordinate system. Note if position is beyond expected travel range.

    Use REF key to display reference point status - unreferenced axes can cause false position readings

  2. 2

    Verify software travel limits

    Access MOD function, select machine parameters, check MP1010 (Z- limit) and MP1020 (Z+ limit) values match machine specifications.

    Only modify travel limits if you have machine documentation - incorrect values can cause crashes

  3. 3

    Perform controlled retraction

    Use Manual mode with reduced feedrate override (10-25%) to move Z-axis away from limit position using handwheel or direction keys.

    If axis won't move, try EMERGENCY STOP reset followed by reference point return

  4. 4

    Re-establish reference point

    Execute reference point return for Z-axis using REF key, then verify position accuracy with known reference tool or workpiece.

    Ensure clear path before reference point return to prevent collisions

DIY Feasiblehigh confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Servo drive hardware failure
  • ·Mechanical component replacement needed
  • ·Multiple related alarms persist

Prevention

  • Regular way lubrication maintenance
  • Periodic encoder cable inspection
  • Proper work coordinate system setup procedures
  • Regular servo parameter backup

Common Mistakes

  • Ignoring gradual position accuracy degradation
  • Modifying travel limits without documentation
  • Operating with intermittent encoder faults
  • Inadequate chip and coolant management