Servo/Axis · Intermediate · 30-120 minutes
Heidenhain 905-2787 - Faulty behavior with oversize
The Heidenhain 905-2787 alarm, 'Faulty behavior with oversize,' typically indicates a discrepancy in the end position shift during operation, often due to mechanical misalignment or encoder issues. The most likely fix involves checking and recalibrating the position feedback system or inspecting for mechanical obstructions. Addressing this promptly prevents further damage to the machine's accuracy and components.
Heidenhain 905-2787 - Faulty behavior with oversize
Faulty behavior with oversize
Heidenhain TNC error 905-2787: Faulty behavior with oversize. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.
Root Cause Summary
The Heidenhain 905-2787 alarm, 'Faulty behavior with oversize,' typically indicates a discrepancy in the end position shift during operation, often due to mechanical misalignment or encoder issues. The most likely fix involves checking and recalibrating the position feedback system or inspecting for mechanical obstructions. Addressing this promptly prevents further damage to the machine's accuracy and components.
Safety
Causes and Fixes
Inspect Axis Alignment
Use a precision level or dial indicator to check the alignment of the affected axis. Compare readings against the machine's original specifications in the Heidenhain manual.
Mark reference points before adjustments to track changes accurately.
Ensure machine is powered off and locked out to prevent accidental movement.
Check for Mechanical Play
Manually move the axis to detect excessive play or looseness in components like bearings or couplings. Tighten or replace parts as necessary.
Use a torque wrench to ensure bolts are tightened to manufacturer specs.
Wear protective gloves to avoid injury from sharp edges.
Realign and Test
Realign components using shims or adjustment screws as per the manual. Run a test cycle to verify if the error persists after realignment.
Document all adjustments for future reference in case of recurring issues.
Do not overtighten components, as this can cause additional stress.
Call a technician if: