Heidenhain codes
HeidenhainCommunicationIntermediate30-120 minutes

905-275A

Heidenhain 905-275A - Transmission ratio

Transmission ratio

Heidenhain TNC error 905-275A: Transmission ratio. This alarm indicates a fault or error condition on the Heidenhain TNC control that requires investigation. Refer to the Heidenhain NC error message documentation for the specific cause and remedy for this alarm code.

Root Cause Summary

HEIDENHAIN alarm 905-275A indicates a transmission ratio error in the communication system between the TNC control and connected components. This typically occurs when encoder feedback ratios don't match configured parameters or when there's a mismatch in the drive system transmission calculations.

Safety

  • Refer to Heidenhain service manual
  • Ensure qualified technician performs repairs

Causes and Fixes

  1. 1

    Access Machine Parameters

    Press MOD key, select 'Machine Parameters', navigate to MP7500 series parameters for the affected axis.

    Always backup current parameters before making changes using the data backup function.

  2. 2

    Verify Transmission Ratio Settings

    Check MP7500.x (numerator) and MP7501.x (denominator) values match your machine's actual gear ratios and lead screw pitch.

    Incorrect ratios can cause dangerous axis movements - verify with machine documentation.

  3. 3

    Calculate and Update Parameters

    Calculate correct ratio: (motor revolutions × gear ratio) / (table movement per motor revolution). Update MP7500.x and MP7501.x accordingly.

    Use the TNC's built-in calculator function (CALC key) for precise calculations.

  4. 4

    Restart Control System

    Perform a complete TNC restart (CTRL+ALT+DEL) to activate new transmission ratio parameters.

    Ensure all axes are in safe positions before restart.

DIY Feasiblemedium confidence

Call a technician if:

  • ·Encoder replacement required
  • ·Drive amplifier configuration needed
  • ·Mechanical transmission ratio unknown

Prevention

  • Regular backup of machine parameters
  • Document actual mechanical ratios during installation
  • Periodic fieldbus diagnostics checks

Common Mistakes

  • Confusing gear ratio direction (multiply vs divide)
  • Forgetting to restart TNC after parameter changes
  • Not backing up parameters before modifications

Seeing Multiple Alarms?

Seeing another alarm with this one? Enter the code.

Get machine-aware diagnosis

AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.

Start free

Was this guide helpful?

Always verify with your machine manual or a certified technician before performing service procedures.