Heidenhain Controller
Safety · Intermediate · 30-120 minutes
HEIDENHAIN 330-00BE - CC error in cut-out channel STO.A.x, RDY signal missing
Alarm 330-00BE indicates a failure in the STO (Safe Torque Off) safety circuit's cutout channel A for spindle power modules, where the RDY (Ready) signal is not being received properly during the CC (Control Cabinet) safety function test. This typically occurs when power modules fail to report readiness status or when there are communication issues in the safety circuit chain.
HEIDENHAIN 330-00BE - CC error in cut-out channel STO.A.x, RDY signal missing
CC error in cut-out channel STO.A.x, RDY signal missing
An error occurred during initialization or cyclic operation of the internal I/O hardware. This affects communication with SPI modules.
Root Cause Summary
Alarm 330-00BE indicates a failure in the STO (Safe Torque Off) safety circuit's cutout channel A for spindle power modules, where the RDY (Ready) signal is not being received properly during the CC (Control Cabinet) safety function test. This typically occurs when power modules fail to report readiness status or when there are communication issues in the safety circuit chain.
Safety
Causes and Fixes
Check Power Module Status LEDs
Examine all spindle power modules for fault LEDs. Look for red fault indicators or missing green ready lights on each module.
Ensure main power is locked out before opening cabinet doors
Verify Module Supply Voltages
Use multimeter to check 24VDC supply to each power module. Measure at terminals X1:1(+24V) and X1:2(0V) on each module.
Low supply voltage below 22VDC can cause RDY signal failures
Test RDY Output Signals
Measure RDY signal output at each power module terminal X2:5. Should read 24VDC when module is ready.
Use oscilloscope to check for signal integrity and timing issues
Replace Faulty Power Module
If a module shows no RDY output despite proper supply voltage, replace the defective power module with identical part number.
Record all parameter settings before module replacement
Call a technician if:
Prevention
Common Mistakes
Seeing Multiple Alarms?
Seeing another alarm with this one? Enter the code.
AxisMD logs alarms against your actual machines, tracks patterns, and gives AI context your manual doesn't have.
Start freeWas this guide helpful?
Always verify with your machine manual or a certified technician before performing service procedures.